Solar backup battery middle size UPS battery SL12-42

Short Description:

Standard: National Standard 
Rated voltage (V): 12 
Rated capacity (Ah):42
Battery size (mm): 197*165*170*170
Reference Weight (kg): 13.3
Terminal direction: + - 
OEM Service: supported 
Origin: Fujian, China. 


Product Detail

Product Tags

FEATURES

1.Features: AGM separator paper reduces battery internal resistance, prevents micro-short circuit, and prolongs cycle life.

2.Material: ABS battery shell material, impact resistance, corrosion resistance, high temperature resistance. High purity material.

3.Technology: The sealed maintenance-free technology makes the battery seal better, without daily maintenance, and the bumpy state prevents liquid leakage.

4.Application field: Telecom system, outdoor backup power supply system, stionary/standby power system, industrial data base system, etc

QUALITY

1. 100% Pre-delivery inspection to ensure stable quality and reliable performance.

2. Pb-Ca grid alloy battery plate,Refined temperature-controlled curing new process.

3. Low internal resistance, good high rate discharge performance.

4. Excellence high-and-low temperature performance, working temperature ranging from -25℃ to 50℃.

5. Design float service life: 5-7 years

COMPANY PROFILE

Business Type: Manufacturer/Factory.
Main Products: Lead acid batteries, VRLA batteries, Motorcycle batteries, storage batteries, Electronic Bike batteries, Automotive batteries and Lithium batteries.
Year of Establish: 1995.
Management System Certificate: ISO19001, ISO16949.
Location: Xiamen, Fujian.

EXPORT MARKET

1. Southeast Asia: India, Indonesia, Malaysia, Philippine, Myanmar, Vietnam, Cambodia, etc.

2. Africa: South Africa, Algeria, Nigeria, Kenya, Mozambique, Egypt, etc.

3. Middle-East: Yemen, Iraq, Turkey, Lebanon, etc.

4. Latin and South American: Mexico, Colombia, Brazil, Peru, etc.

5. Europe: Italy, UK, Spain, Portugal, Ukraine, etc.

6. North America: USA, Canada.

PAYMENT&DELIVERY

Payment Terms: TT, D/P, LC, OA, etc.
Delivery Details: within 30-45 days after order confirmed.

PRODUCT SKU
Model Voltage Capacity Intemal Dimensions Terminal Weight Terminal
(V) (Ah) Resistance (mm) Type (kg) Direction
(mΩ)
SL6-36 6 36 4.5 162*88*164*170 F2 5.6 -  +
SL6-42 6 42 4.2 162*88*164*170 F2 6.1 -  +
SL6-100 6 100 3 194*170*205*210 F14 15.5 -  +
SL6-150 6 150 2.5 260*180*245*250 F13 23 -  +
SL6-180 6 180 2.2 307*169*220*225 F13 27 -  +
SL6-200A 6 200 2 307*169*220*225 F13 29 -  +
SL6-200 6 200 2 321*176*226*229 F13 29.5 -  +
SL6-300 6 300 1.5 295*178*345*348 F13 47 -  +
SL12-24L 12 24 195*130*155*166 F14 8.2
29 195*130*155*166 F14 9.1
SL12-31 12 31 11 195*130*155*166 F14 9.6 +   -
SL12-33 12 33 10 195*130*155*166 F14 10 +   -
SL12-35 12 35 9 195*130*155*166 F14 10.5 +   -
SL12-38 12 38 9 197*165*170*170 F14 12 -  +
SL12-40 12 40 8.5 197*165*170*170 F14 12.5 -  +
SL12-42 12 42 197*165*170*170 F14 13.3 -  +
197*165*170*170 F14 13.5 -  +
SL12-45 12 45 8 197*165*170*170 F14 14 -  +
SL12-33S 12 33 229*138*211*214 F14 13
40 229*138*211*214 F14 13.6
45 229*138*211*214 F14 15
SL12-50 12 50 7.5 229*138*211*214 F14 15.5 +   -
SL12-55 12 55 7 229*138*211*214 F14 16.5 +   -
SL12-50A 12 50 7.5 229*138*205*210 F19 15.5 +   -
SL12-55A 12 50 7.5 260*168*211*214 F14 18.5
SL12-60 12 60 7 260*168*211*214 F14 20 +   -
SL12-70 12 70 6.5 260*168*211*214 F14 21.5 +   -
SL12-75 12 75 260*168*211*214 F14 22.5 +   -
SL12-80 12 80 5.5 260*168*211*214 F14 23 +   -
SL12-40S 12 40 350*167*179*179 F14 15.7
SL12-50S 12 50 F14 17
SL12-54 12 54 F14 18
12 60 F14 19
SL12-65 12 65 6 F14 20 -  +
SL12-70A 12 70 F14 21
SL12-80A 12 80 6 F14 23.5 -  +
SL12-90V 12 70 306*169*211*214 F14 23.5
SL12-90E 12 90 5 306*169*211*214 F14 26 +   -
SL12-90 12 90 5 306*169*211*214 F14 26.5 +   -
SL12-70S 12 70 330*171*214*220 F14 24.5
6GMF80S 12 80 330*171*214*220 F14 25.5
SL12-90AE 12 90 5 330*171*214*220 F14 27 +   -
SL12-90A 12 90 5 330*171*214*220 F14 27.5 +   -
SL12-100E 12 100 4.5 330*171*214*220 F14 29 +   -
SL12-100 12 100 4.5 330*171*214*220 F14 29.5 +   -
SL12-110 12 110 4.5 330*171*214*220 F14 32 +   -
SL12-130 12 130 330*171*214*220 F14 33.4
SL12-120A 12 120 4 409*176*225*225 F13 34 +   -
SL12-90S 12 90 5 406*173*208*238 F13 29.5 +   -
SL12-100S 12 100 4.5 F13 31 +   -
SL12-110S 12 110 4.5 F13 32 +   -
SL12-120 12 120 4 F13 34 +   -
SL12-120B 12 120 4 280*265*207*227 36.5
SL12-130B 12 130 38.5
SL12-135 12 135 340*172*282*284 F13 40.5
SL12-135 12 135 3.5 F13 42.5 +   -
SL12-110S 12 110 485*172*240*240 F13 35
SL12-120S 12 120 F13 37.5
SL12-135S 12 135 3.5 F13 40.5 +   -
SL12-150 12 150 3.5 F13 43 +   -
SL12-150 12 150 530*207*210*213 F13
SL12-160 12 160 4 F13 49.5
SL12-180 12 180 3.5 F13 52.5
SL12-180S 12 180 3.5 522*238*218*221 F13 55.5
SL12-190S 12 190 F13 57
SL12-200 12 200 3 F12 59.5
SL12-220 12 220 F13 61
SL12-225 12 225 F13 63
SL12-250 12 250 2.6 521*269*220*223 F13 71
PACKING&SHIPMENT

OEM solar battery backup

Packaging: Kraft brown outer box/Colored boxes.
FOB XIAMEN or other ports.
Lead Time: 20-25 Working Days

MAINTENANCE CHECKLIST

As per the epidemic of COVID-19, many places are locked down or carrying out quarantine policy, which would cause the consumption ability going down and the longer the storage time of the cargoes/goods. Considering the charateristics of lead acid batteries,here is the lead acid battery maintenance checklist.

Recharge:

recharge voltage 14.4V-14.8V, recharge currency 0.1C, constant voltage charging time: 10-15 hours.

If not recharged, the batteries may not be working due to high internal resistance.

Recharge 30 mins of the dry charged batteries if it is stocked in warehouse more than one year; or the battery internal plates are oxidated in winter season with low temperature environment (recharge voltage 14.4V-14.8V, recharge currency 0.1C).

Do not turn the battery upside downin case acid leakage from the safety valve.

If leakage happening, please take the leaking batteries from the others and clean it; in case the acid causes batteries short circuit. After cleaning the leaking batteries, please recharge the batteries as above steps.

Songli Battery is a global lead-acid battery technology expert. In addition, we have become one of the world's most successful independent battery manufacturers.We sincererly thank you for your always trust on our battery products and service, and we are also improving ourselves and products to provide you more excellent products and service.

Recomended temperature for  lead acid battery maintenance:

10~25℃(High temperature would speed up the battery self-discharge). Kepp the warehouse clean, ventilated and dry, and avoid direct sunlight or excessive humidity.

lead acid battery maintenance checklist

Warehouse management principle: First in First Out.

VRlA battery

Those batteries which are stocked in warehouse with longer time sold in priority,in case the battery voltage under low. It is better to divide different storage areas in the warehouse according to the arrival date as shown on the cargoes package.

Testing and inspecting of the sealed MF batteries’voltage every 3 months in case the batteries’ voltage under low or cannot start up.

Take the 12V series battery for instance, pleasure recharge the batteries if the voltage is under 12.6V; or the battery may not start up.

Lead acid batteries stocked in the warehouse more than 6 months, please do the voltage inpection and recharge the batteries before selling to essure the batteries in normal status.

battery charging,TCS battery,valve regulated lead acid battery

Steps of battery recharge and discharge:

 

①Battery Charge: charge voltage 14.4V-14.8V, charging currency:0.1C,constant voltage charging time:4 hours.

②Battery Discharge:discharge currency:0.1C, End of discharge voltage 10.5V of each battery.

③Battery Recharge:recharge voltage 14.4V-14.8V, recharge currency: 0.1C,constant voltage charging time: 10-15 hours.

As bellowing picture shown, please coordinate with our sales team if there is any questions about the usage of the device and then we could provide you the operation video.

lead acid battery maintenance checklist (4)

Steps of manual recharge and discharge operation:

3.2.1.Charge: charge voltage 14.4V-14.8V, charge currency:0.1C,constant voltage charging time:4 hours.

If operation video needed, please inquiry with our sales team. Thanks.

lead acid battery maintenance checklist ,vrla battery,valve regulated lead acid battery ,agm battery,

Discharge:

Quick discharge the batteries at 1C discharge rate until the battery voltage down to 10.5V. If operation video needed, please inquiry with our sales team. Thanks.

VRLA battery,lead acid battery,sla battery,